Re: [PATCH v2 1/2] dt-bindings: thermal: convert st,stih407-thermal to DT schema

From: Raphaël Gallais-Pou
Date: Wed Mar 06 2024 - 02:53:31 EST




Le 04/03/2024 à 19:40, Rob Herring a écrit :
On Fri, Mar 01, 2024 at 06:47:28PM +0100, Raphael Gallais-Pou wrote:
'st,passive_colling_temp' does not appear in the device-tree, and 'reg'
is missing in the device description.

Convert st,stih407-thermal binding to DT schema format in order to clean
unused 'st,passive_cooling_temp' and add missing 'reg' property.

Signed-off-by: Raphael Gallais-Pou <rgallaispou@xxxxxxxxx>


Hi Rob,

..

+ interrupts:
+ description:
+ For thermal sensors for which no interrupt has been defined, a polling
+ delay of 1000ms will be used to read the temperature from device.

maxItems: 1

Ack.

+
+ '#thermal-sensor-cells': true

const: 1

Also, not in the original binding, so please state in the commit msg
why you are adding it.

I have mixed feeling regarding the value. Wouldn't this better be 'const: 0' ?

In the thermal-sensor binding it is specified that it should be 0 for single sensor nodes, which is our case.


+
+required:
+ - compatible
+ - reg
+ - clocks
+ - clock-names
+
+unevaluatedProperties: false
+
+examples:
+ - |
+ #include <dt-bindings/interrupt-controller/arm-gic.h>
+ temperature-sensor@91a0000 {
+ compatible = "st,stih407-thermal";
+ reg = <0x91a0000 0x28>;
+ clock-names = "thermal";
+ clocks = <&CLK_SYSIN>;
+ interrupts = <GIC_SPI 205 IRQ_TYPE_EDGE_RISING>;
+ #thermal-sensor-cells = <0>;

If I misunderstand something and the value must be 1 then I will also change the value here and in the dt patches of the serie.

Regards,
Raphaël
+ };
+...