[PATCH net-next v1 3/9] net: dsa: qca: ar9331: reorder MDIO write sequence

From: Oleksij Rempel
Date: Sat Apr 03 2021 - 07:50:18 EST


In case of this switch we work with 32bit registers on top of 16bit
bus. Some registers (for example access to forwarding database) have
trigger bit on the first 16bit half of request and the result +
configuration of request in the second half. Without this this patch, we would
trigger database operation and overwrite result in one run.

To make it work properly, we should do the second part of transfer
before the first one is done.

So far, this rule seems to work for all registers on this switch.

Signed-off-by: Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx>
---
drivers/net/dsa/qca/ar9331.c | 7 ++++---
1 file changed, 4 insertions(+), 3 deletions(-)

diff --git a/drivers/net/dsa/qca/ar9331.c b/drivers/net/dsa/qca/ar9331.c
index ca2ad77b71f1..9a5035b2f0ff 100644
--- a/drivers/net/dsa/qca/ar9331.c
+++ b/drivers/net/dsa/qca/ar9331.c
@@ -837,16 +837,17 @@ static int ar9331_mdio_write(void *ctx, u32 reg, u32 val)
return 0;
}

- ret = __ar9331_mdio_write(sbus, AR9331_SW_MDIO_PHY_MODE_REG, reg, val);
+ ret = __ar9331_mdio_write(sbus, AR9331_SW_MDIO_PHY_MODE_REG, reg + 2,
+ val >> 16);
if (ret < 0)
goto error;

- ret = __ar9331_mdio_write(sbus, AR9331_SW_MDIO_PHY_MODE_REG, reg + 2,
- val >> 16);
+ ret = __ar9331_mdio_write(sbus, AR9331_SW_MDIO_PHY_MODE_REG, reg, val);
if (ret < 0)
goto error;

return 0;
+
error:
dev_err_ratelimited(&sbus->dev, "Bus error. Failed to write register.\n");
return ret;
--
2.29.2