Re: 2.6.18.2: sporadic SATA port resets (Broadcom BCM5785 (HT1000))

From: Tejun Heo
Date: Sun Feb 11 2007 - 17:20:43 EST


Hello, Emmeran.

There is no logged error on drive's side. Only timeouts on host's side with BMDMA engine running. I dunno specifics of the severwork controller but many controllers with BMDMA interface timeouts the command if transmission failure occurs, so my primary suspect is still hardware transmission problem which seems quite common in SATA world.

Can you try the followings?

1. Use different cable and connect the hdd to different hdd.

2. If possible, connect the harddisk to different power supply. (I know you have juicy PSU but just in case)

Probably applying this to only one machine and leaving the other alone as control is a good idea.

Thanks.

--
tejun
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html