Re: 2.6.18.2: sporadic SATA port resets (Broadcom BCM5785 (HT1000))

From: Emmeran Seehuber
Date: Sat Feb 10 2007 - 03:43:10 EST


Am Saturday 10 February 2007 schrieb Tejun Heo:
> Hmmm... Raptor not supporting SMART.  That's weird.  Please try
> 'smartctl -d ata -a /dev/sda'.

The output is attached.

cu,
Emmy
smartctl version 5.36 [x86_64-unknown-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model: WDC WD1500ADFD-00NLR1
Serial Number: WD-WMAP41246348
Firmware Version: 20.07P20
User Capacity: 150.039.945.216 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 7
ATA Standard is: Not recognized. Minor revision code: 0x1d
Local Time is: Sat Feb 10 09:31:27 2007 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (4783) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 72) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 200 200 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0007 170 170 021 Pre-fail Always - 4533
4 Start_Stop_Count 0x0032 100 100 040 Old_age Always - 59
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x000a 200 200 051 Old_age Always - 0
9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 2232
10 Spin_Retry_Count 0x0012 100 253 051 Old_age Always - 0
11 Calibration_Retry_Count 0x0012 100 253 051 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 59
194 Temperature_Celsius 0x0022 118 116 000 Old_age Always - 29
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0012 200 200 000 Old_age Always - 0
199 UDMA_CRC_Error_Count 0x000a 200 253 000 Old_age Always - 5
200 Multi_Zone_Error_Rate 0x0008 200 200 051 Old_age Offline - 0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.