Re: sym/ncr53c8xx phase error still present in 2.2.7

Shaw Carruthers (shaw@shawc.demon.co.uk)
Thu, 6 May 1999 23:15:18 +0100 (GMT+0100)


I have now completed my tests and I can reliably trigger the error after 1
or 2 minutes.

The error occurs when the tape stops streaming at the end of a tape buffer
( 16MB of data). I guess the ide tape drive chews up a lot of bus time
when it is settling so I will look into the parameters of the IDE tape
driver and see if they affect the problem.

I still get the problem with safe SCSI and both read and write caching
disabled.

-- 
Shaw Carruthers - shaw@shawc.demon.co.uk
London SW14 7JW UK
This is not a sig( with homage to Magritte).
  