Re: [PATCH] net: dsa: mv88e6xxx: fix usable ports on 88e6020

From: Lukasz Majewski
Date: Tue Mar 26 2024 - 11:54:50 EST


Hi Matthias,

> On Tue, 2024-03-26 at 14:34 +0100, Lukasz Majewski wrote:
> > Hi Matthias,
> >
> > > From: Michael Krummsdorf <michael.krummsdorf@xxxxxxxxxxxx>
> > >
> > > The switch has 4 ports with 2 internal PHYs, but ports are
> > > numbered up to 6, with ports 0, 1, 5 and 6 being usable.
> > >
> > > Fixes: 71d94a432a15 ("net: dsa: mv88e6xxx: add support for
> > > MV88E6020 switch") Signed-off-by: Michael Krummsdorf
> > > <michael.krummsdorf@xxxxxxxxxxxx> Signed-off-by: Matthias Schiffer
> > > <matthias.schiffer@xxxxxxxxxxxxxxx> ---
> > >
> > > I was unfortunately too busy to notice the issue when the patch
> > > this Fixes was resubmitted in my name. It would have been better
> > > to change my From into a Based-on-patch-by or similar when
> > > modifying it
> >
> > The "discussion" about this work was lasting at least a few months
> > with several iterations and changing the design decisions ...
> >
> > > - and
> > > the final version obviously wasn't even tested on an 88E6020...
> >
> >
> > Can you share on which kernel version have you tested the patch that
> > you claim that testing was omitted?
>
> Hi Lukasz,
>
> we are currently testing with commit 71d94a432a15 backported onto a
> recent Linux 6.1.y. At least on this kernel version, the driver will
> reject a Device Tree configuration that uses the ports 5 and 6
> (rightfully so, as num_ports is set to 4), leaving only the
> internal-PHY ports 0 and 1, and none of the *MII ports that are
> likely to be used as CPU ports.
>
> So if the accepted version worked fine for you, your configuration
> possibly only used the first two ports,

And then the penny has dropped....


switch@10 {
compatible = "marvell,mv88e6250";
reg = <0x10>;

ports {
#address-cells = <1>;
#size-cells = <0>;

port@0 {
reg = <0>;
label = "lan1";
};

port@1 {
reg = <1>;
label = "lan2";
};

port@6 {
reg = <6>;
label = "cpu";
phy-mode = "rmii";
ethernet = <&fec2>;

fixed-link {
speed = <100>;
full-duplex;
};
};
};
};



> or newer kernels somehow
> ignore num_ports when determining if a port number is valid.
>
> We should be able to repeat our test on a newer kernel next week if
> needed.

I think that considering the above snippet - customer was using only
port 0 and 1.

>
> Best regards,
> Matthias
>
>
> >
> > >
> > >
> > > drivers/net/dsa/mv88e6xxx/chip.c | 6 +++++-
> > > 1 file changed, 5 insertions(+), 1 deletion(-)
> > >
> > > diff --git a/drivers/net/dsa/mv88e6xxx/chip.c
> > > b/drivers/net/dsa/mv88e6xxx/chip.c index
> > > 9ed1821184ece..c95787cb90867 100644 ---
> > > a/drivers/net/dsa/mv88e6xxx/chip.c +++
> > > b/drivers/net/dsa/mv88e6xxx/chip.c @@ -5503,8 +5503,12 @@ static
> > > const struct mv88e6xxx_info mv88e6xxx_table[] = { .family =
> > > MV88E6XXX_FAMILY_6250, .name = "Marvell 88E6020",
> > > .num_databases = 64,
> > > - .num_ports = 4,
> > > + /* Ports 2-4 are not routed to pins
> > > + * => usable ports 0, 1, 5, 6
> > > + */
> > > + .num_ports = 7,
> > > .num_internal_phys = 2,
> > > + .invalid_port_mask = BIT(2) | BIT(3) | BIT(4),
> > > .max_vid = 4095,
> > > .port_base_addr = 0x8,
> > > .phy_base_addr = 0x0,
> >
> >
> >
> >
> > Best regards,
> >
> > Lukasz Majewski
> >
> > --
> >
> > DENX Software Engineering GmbH, Managing Director: Erika Unter
> > HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell,
> > Germany Phone: (+49)-8142-66989-59 Fax: (+49)-8142-66989-80 Email:
> > lukma@xxxxxxx Achtung externe E-Mail: Öffnen Sie Anhänge und Links
> > nur, wenn Sie wissen, dass diese aus einer sicheren Quelle stammen
> > und sicher sind. Leiten Sie die E-Mail im Zweifelsfall zur Prüfung
> > an den IT-Helpdesk weiter. Attention external email: Open
> > attachments and links only if you know that they are from a secure
> > source and are safe. In doubt forward the email to the IT-Helpdesk
> > to check it.
> >
> >  
>




Best regards,

Lukasz Majewski

--

DENX Software Engineering GmbH, Managing Director: Erika Unter
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-59 Fax: (+49)-8142-66989-80 Email: lukma@xxxxxxx