[PATCH] iio: pressure: hsc030pa: Use spi_read()

From: Christophe JAILLET
Date: Sun Mar 24 2024 - 08:36:44 EST


Use spi_read() instead of hand-writing it.
It is less verbose.

Signed-off-by: Christophe JAILLET <christophe.jaillet@xxxxxxxxxx>
---
Compile test only
---
drivers/iio/pressure/hsc030pa_spi.c | 7 +------
1 file changed, 1 insertion(+), 6 deletions(-)

diff --git a/drivers/iio/pressure/hsc030pa_spi.c b/drivers/iio/pressure/hsc030pa_spi.c
index 818fa6303454..337eecc577d2 100644
--- a/drivers/iio/pressure/hsc030pa_spi.c
+++ b/drivers/iio/pressure/hsc030pa_spi.c
@@ -23,14 +23,9 @@
static int hsc_spi_recv(struct hsc_data *data)
{
struct spi_device *spi = to_spi_device(data->dev);
- struct spi_transfer xfer = {
- .tx_buf = NULL,
- .rx_buf = data->buffer,
- .len = HSC_REG_MEASUREMENT_RD_SIZE,
- };

msleep_interruptible(HSC_RESP_TIME_MS);
- return spi_sync_transfer(spi, &xfer, 1);
+ return spi_read(spi, data->buffer, HSC_REG_MEASUREMENT_RD_SIZE);
}

static int hsc_spi_probe(struct spi_device *spi)
--
2.44.0