Re: [PATCH v2 1/2] platform/x86: wmi: Support reading/writing 16 bit EC values

From: Ilpo Järvinen
Date: Fri Mar 08 2024 - 03:01:38 EST


On Thu, 7 Mar 2024, Armin Wolf wrote:

> The ACPI EC address space handler currently only supports
> reading/writing 8 bit values. Some firmware implementations however
> want to access for example 16 bit values, which is prefectly legal
> according to the ACPI spec.
>
> Add support for reading/writing such values.
>
> Tested on a Dell Inspiron 3505 and a Asus Prime B650-Plus.
>
> Signed-off-by: Armin Wolf <W_Armin@xxxxxx>

> @@ -1162,27 +1188,28 @@ acpi_wmi_ec_space_handler(u32 function, acpi_physical_address address,
> u32 bits, u64 *value,
> void *handler_context, void *region_context)
> {
> - int result = 0;
> - u8 temp = 0;
> + int bytes = bits / BITS_PER_BYTE;
> + int ret;
> +
> + if (!value)
> + return AE_NULL_ENTRY;
>
> - if ((address > 0xFF) || !value)
> + if (bytes > sizeof(*value))
> return AE_BAD_PARAMETER;
>
> - if (function != ACPI_READ && function != ACPI_WRITE)
> + if (address > U8_MAX || address + bytes > U8_MAX)

This doesn't look correct. With address = 0xff and bits = 8 this will
return AE_BAD_PARAMETER, is that intensional?

--
i.