Re: [PATCH v2 2/5] nvme-fc: do not retry when auth fails or connection is refused

From: Hannes Reinecke
Date: Wed Feb 21 2024 - 10:54:34 EST


On 2/21/24 14:24, Daniel Wagner wrote:
There is no point in retrying to connect if the authentication fails.

Connection refused is also issued from the authentication path, thus
also do not retry.

Reviewed-by: Christoph Hellwig <hch@xxxxxx>
Signed-off-by: Daniel Wagner <dwagner@xxxxxxx>
---
drivers/nvme/host/fc.c | 2 ++
1 file changed, 2 insertions(+)

diff --git a/drivers/nvme/host/fc.c b/drivers/nvme/host/fc.c
index a5b29e9ad342..b81046c9f171 100644
--- a/drivers/nvme/host/fc.c
+++ b/drivers/nvme/host/fc.c
@@ -3312,6 +3312,8 @@ nvme_fc_reconnect_or_delete(struct nvme_fc_ctrl *ctrl, int status)
ctrl->cnum, status);
if (status > 0 && (status & NVME_SC_DNR))
recon = false;
+ if (status == NVME_SC_AUTH_REQUIRED || status == -ECONNREFUSED)
+ recon = false;
} else if (time_after_eq(jiffies, rport->dev_loss_end))
recon = false;
Is this still required after the patchset to retry authentication errors?

Cheers,

Hannes
--
Dr. Hannes Reinecke Kernel Storage Architect
hare@xxxxxxx +49 911 74053 688
SUSE Software Solutions GmbH, Frankenstr. 146, 90461 Nürnberg