[PATCH] perf list: fix short description for some cache events

From: Thomas Richter
Date: Wed Feb 21 2024 - 04:20:13 EST


Correct the short description of the following events:
DCW_REQ, DCW_REQ_CHIP_HIT, DCW_REQ_DRAWER_HIT, DCW_REQ_IV,
DCW_ON_CHIP, DCW_ON_CHIP_IV, DCW_ON_CHIP_CHIP_HIT,
DCW_ON_CHIP_DRAWER_HIT, CW_ON_MODULE, DCW_ON_DRAWER,
DCW_OFF_DRAWER, IDCW_ON_MODULE_IV, IDCW_ON_MODULE_CHIP_HIT,
IDCW_ON_MODULE_DRAWER_HIT, IDCW_ON_DRAWER_IV, IDCW_ON_DRAWER_CHIP_HIT,
IDCW_ON_DRAWER_DRAWER_HIT, IDCW_OFF_DRAWER_IV, IDCW_OFF_DRAWER_CHIP_HIT,
IDCW_OFF_DRAWER_DRAWER_HIT, ICW_REQ, ICW_REQ_IV, CW_REQ_CHIP_HIT,
ICW_REQ_DRAWER_HIT, ICW_ON_CHIP, ICW_ON_CHIP_IV, ICW_ON_CHIP_CHIP_HIT,
ICW_ON_CHIP_DRAWER_HIT, ICW_ON_MODULE and ICW_OFF_DRAWER.

The second Cache should be L2-Cache.

Output before (display diff of the first four events)
# perf list -d
DCW_REQ
[Directory Write Level 1 Data Cache from Cache. Unit: cpum_cf]
DCW_REQ_CHIP_HIT
[Directory Write Level 1 Data Cache from Cache with Chip HP \
Hit. Unit: cpum_cf]
DCW_REQ_DRAWER_HIT
[Directory Write Level 1 Data Cache from Cache with Drawer \
HP Hit. Unit: cpum_cf]
DCW_REQ_IV
[Directory Write Level 1 Data Cache from Cache with Intervention. \
Unit: cpum_cf]

Output after:
# perf list -d
DCW_REQ
[Directory Write Level 1 Data Cache from L2-Cache. Unit: cpum_cf]
DCW_REQ_CHIP_HIT
[Directory Write Level 1 Data Cache from L2-Cache with Chip HP \
Hit. Unit: cpum_cf]
DCW_REQ_DRAWER_HIT
[Directory Write Level 1 Data Cache from L2-Cache with Drawer \
HP Hit. Unit: cpum_cf]
DCW_REQ_IV
[Directory Write Level 1 Data Cache from L2-Cache with \
Intervention. Unit: cpum_cf]

Fixes: 7f76b3113068 ("perf list: Add IBM z16 event description for s390")
Reported-by: Andreas Krebbel <krebbel@xxxxxxxxxxxxx>
Signed-off-by: Thomas Richter <tmricht@xxxxxxxxxxxxx>
Acked-by: Andreas Krebbel <krebbel@xxxxxxxxxxxxx>
---
.../pmu-events/arch/s390/cf_z16/extended.json | 62 +++++++++----------
1 file changed, 31 insertions(+), 31 deletions(-)

diff --git a/tools/perf/pmu-events/arch/s390/cf_z16/extended.json b/tools/perf/pmu-events/arch/s390/cf_z16/extended.json
index c2b10ec1c6e0..02cce3a629cb 100644
--- a/tools/perf/pmu-events/arch/s390/cf_z16/extended.json
+++ b/tools/perf/pmu-events/arch/s390/cf_z16/extended.json
@@ -94,77 +94,77 @@
"Unit": "CPU-M-CF",
"EventCode": "145",
"EventName": "DCW_REQ",
- "BriefDescription": "Directory Write Level 1 Data Cache from Cache",
+ "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache",
"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache."
},
{
"Unit": "CPU-M-CF",
"EventCode": "146",
"EventName": "DCW_REQ_IV",
- "BriefDescription": "Directory Write Level 1 Data Cache from Cache with Intervention",
+ "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Intervention",
"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache with intervention."
},
{
"Unit": "CPU-M-CF",
"EventCode": "147",
"EventName": "DCW_REQ_CHIP_HIT",
- "BriefDescription": "Directory Write Level 1 Data Cache from Cache with Chip HP Hit",
+ "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Chip HP Hit",
"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache after using chip level horizontal persistence, Chip-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "148",
"EventName": "DCW_REQ_DRAWER_HIT",
- "BriefDescription": "Directory Write Level 1 Data Cache from Cache with Drawer HP Hit",
+ "BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Drawer HP Hit",
"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache after using drawer level horizontal persistence, Drawer-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "149",
"EventName": "DCW_ON_CHIP",
- "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache",
+ "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache",
"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache."
},
{
"Unit": "CPU-M-CF",
"EventCode": "150",
"EventName": "DCW_ON_CHIP_IV",
- "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Intervention",
+ "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Intervention",
"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache with intervention."
},
{
"Unit": "CPU-M-CF",
"EventCode": "151",
"EventName": "DCW_ON_CHIP_CHIP_HIT",
- "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Chip HP Hit",
+ "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Chip HP Hit",
"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache after using chip level horizontal persistence, Chip-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "152",
"EventName": "DCW_ON_CHIP_DRAWER_HIT",
- "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Drawer HP Hit",
+ "BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Drawer HP Hit",
"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache using drawer level horizontal persistence, Drawer-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "153",
"EventName": "DCW_ON_MODULE",
- "BriefDescription": "Directory Write Level 1 Data Cache from On-Module Cache",
+ "BriefDescription": "Directory Write Level 1 Data Cache from On-Module L2-Cache",
"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Module Level-2 cache."
},
{
"Unit": "CPU-M-CF",
"EventCode": "154",
"EventName": "DCW_ON_DRAWER",
- "BriefDescription": "Directory Write Level 1 Data Cache from On-Drawer Cache",
+ "BriefDescription": "Directory Write Level 1 Data Cache from On-Drawer L2-Cache",
"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache."
},
{
"Unit": "CPU-M-CF",
"EventCode": "155",
"EventName": "DCW_OFF_DRAWER",
- "BriefDescription": "Directory Write Level 1 Data Cache from Off-Drawer Cache",
+ "BriefDescription": "Directory Write Level 1 Data Cache from Off-Drawer L2-Cache",
"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache."
},
{
@@ -199,140 +199,140 @@
"Unit": "CPU-M-CF",
"EventCode": "160",
"EventName": "IDCW_ON_MODULE_IV",
- "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Intervention",
+ "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Intervention",
"PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache with intervention."
},
{
"Unit": "CPU-M-CF",
"EventCode": "161",
"EventName": "IDCW_ON_MODULE_CHIP_HIT",
- "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Chip Hit",
+ "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Chip Hit",
"PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache using chip horizontal persistence, Chip-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "162",
"EventName": "IDCW_ON_MODULE_DRAWER_HIT",
- "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Drawer Hit",
+ "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Drawer Hit",
"PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache using drawer level horizontal persistence, Drawer-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "163",
"EventName": "IDCW_ON_DRAWER_IV",
- "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Intervention",
+ "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Intervention",
"PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache with intervention."
},
{
"Unit": "CPU-M-CF",
"EventCode": "164",
"EventName": "IDCW_ON_DRAWER_CHIP_HIT",
- "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Chip Hit",
+ "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Chip Hit",
"PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache using chip level horizontal persistence, Chip-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "165",
"EventName": "IDCW_ON_DRAWER_DRAWER_HIT",
- "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Drawer Hit",
+ "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Drawer Hit",
"PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache using drawer level horizontal persistence, Drawer-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "166",
"EventName": "IDCW_OFF_DRAWER_IV",
- "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Intervention",
+ "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Intervention",
"PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache with intervention."
},
{
"Unit": "CPU-M-CF",
"EventCode": "167",
"EventName": "IDCW_OFF_DRAWER_CHIP_HIT",
- "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Chip Hit",
+ "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Chip Hit",
"PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache using chip level horizontal persistence, Chip-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "168",
"EventName": "IDCW_OFF_DRAWER_DRAWER_HIT",
- "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Drawer Hit",
+ "BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Drawer Hit",
"PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache using drawer level horizontal persistence, Drawer-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "169",
"EventName": "ICW_REQ",
- "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache",
+ "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache",
"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced the requestors Level-2 cache."
},
{
"Unit": "CPU-M-CF",
"EventCode": "170",
"EventName": "ICW_REQ_IV",
- "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Intervention",
+ "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Intervention",
"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache with intervention."
},
{
"Unit": "CPU-M-CF",
"EventCode": "171",
"EventName": "ICW_REQ_CHIP_HIT",
- "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Chip HP Hit",
+ "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Chip HP Hit",
"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache using chip level horizontal persistence, Chip-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "172",
"EventName": "ICW_REQ_DRAWER_HIT",
- "BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Drawer HP Hit",
+ "BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Drawer HP Hit",
"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache using drawer level horizontal persistence, Drawer-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "173",
"EventName": "ICW_ON_CHIP",
- "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache",
+ "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache",
"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip Level-2 cache."
},
{
"Unit": "CPU-M-CF",
"EventCode": "174",
"EventName": "ICW_ON_CHIP_IV",
- "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Intervention",
+ "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Intervention",
"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an On-Chip Level-2 cache with intervention."
},
{
"Unit": "CPU-M-CF",
"EventCode": "175",
"EventName": "ICW_ON_CHIP_CHIP_HIT",
- "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Chip HP Hit",
+ "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Chip HP Hit",
"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip Level-2 cache using chip level horizontal persistence, Chip-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "176",
"EventName": "ICW_ON_CHIP_DRAWER_HIT",
- "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Drawer HP Hit",
+ "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Drawer HP Hit",
"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip level 2 cache using drawer level horizontal persistence, Drawer-HP hit."
},
{
"Unit": "CPU-M-CF",
"EventCode": "177",
"EventName": "ICW_ON_MODULE",
- "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Module Cache",
+ "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Module L2-Cache",
"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache."
},
{
"Unit": "CPU-M-CF",
"EventCode": "178",
"EventName": "ICW_ON_DRAWER",
- "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Drawer Cache",
+ "BriefDescription": "Directory Write Level 1 Instruction Cache from On-Drawer L2-Cache",
"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an On-Drawer Level-2 cache."
},
{
"Unit": "CPU-M-CF",
"EventCode": "179",
"EventName": "ICW_OFF_DRAWER",
- "BriefDescription": "Directory Write Level 1 Instruction Cache from Off-Drawer Cache",
+ "BriefDescription": "Directory Write Level 1 Instruction Cache from Off-Drawer L2-Cache",
"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an Off-Drawer Level-2 cache."
},
{
--
2.43.0