Re: [PATCH net-next v3 14/17] dt-bindings: net: pse-pd: Add bindings for PD692x0 PSE controller

From: Oleksij Rempel
Date: Mon Feb 19 2024 - 11:08:28 EST


On Mon, Feb 19, 2024 at 03:31:06PM +0100, Köry Maincent wrote:
> On Fri, 16 Feb 2024 08:47:14 +0100
> Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx> wrote:
> > >
> > > So, either somebody needs to understand 1000BaseT and can say the
> > > proposed binding works, or we explicitly document the binding is
> > > limited to 10BaseT and 100BaseT.
> >
> > I asked the internet and found the answer: Some PSE/PD implementations
> > are not compatible with 1000BaseT.
> >
> > See Figure 33–4—10BASE-T/100BASE-TX Endpoint PSE location overview.
> > Alternative B show a variant where power is injected directly to pairs
> > without using magnetics as it is done for Alternative A (phantom
> > delivery - over magnetics).
> >
> > So, we have following variants of 2 pairs PoE:
> > +---------+---------------+-------------------+---------------------+--------------------+
> > | Variant | Alternative | Polarity | Power Feeding Type |
> > Compatibility with | | | (a/b) | (Direct/Reverse) |
> > (Direct/Phantom) | 1000BaseT |
> > +=========+===============+===================+=====================+====================+
> > | 1 | a | Direct | Phantom | Yes
> > |
> > +---------+---------------+-------------------+---------------------+--------------------+
> > | 2 | a | Reverse | Phantom | Yes
> > |
> > +---------+---------------+-------------------+---------------------+--------------------+
> > | 3 | b | Direct | Phantom | Yes
> > |
> > +---------+---------------+-------------------+---------------------+--------------------+
> > | 4 | b | Reverse | Phantom | Yes
> > |
> > +---------+---------------+-------------------+---------------------+--------------------+
> > | 5 | b | Direct | Direct | No
> > |
> > +---------+---------------+-------------------+---------------------+--------------------+
> > | 6 | b | Reverse | Direct | No
> > |
> > +---------+---------------+-------------------+---------------------+--------------------+
>
> Maybe we could remove the polarity column on this table as it does not bring
> more information. It is also already explained on the PI pinout alternatives
> table.

Ack. I'm still not sure if "Phantom" is correct description.

>
> Also we should document that a 4pairs PSE supporting only 10/100BaseT (which
> mean no magnetics on pinout AlternativeB) may not be compatible with a 4pairs
> 1GBaseT PD.

Ack. s/may not/is not/ :) and 4pairs PSE is not always compatible with
PoE4 as well. I assume this kind of knowledge we will get from PSE
driver.

Regards,
Oleksij

--
Pengutronix e.K. | |
Steuerwalder Str. 21 | http://www.pengutronix.de/ |
31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |