[PATCH v3 01/10] dt-bindings: iio: pressure: honeywell,mprls0025pa.yaml improvements

From: Petre Rodan
Date: Fri Dec 29 2023 - 04:25:30 EST


Define enum inside the honeywell,transfer-function property block.

Set the correct irq edge in the example block.
Based on the datasheet, in table 13 on page 11:
"End-of-conversion indicator: This pin is set high when a measurement
and calculation have been completed and the data is ready to be
clocked out"

Add description on End-of-conversion interrupt.

Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx>
Co-developed-by: Andreas Klinger <ak@xxxxxxxxxxxxx>
Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx>
Signed-off-by: Petre Rodan <petre.rodan@xxxxxxxxxxxxxxx>
---
v2 -> v3 no changes

.../bindings/iio/pressure/honeywell,mprls0025pa.yaml | 7 ++++++-
1 file changed, 6 insertions(+), 1 deletion(-)

diff --git a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml
index d9e903fbfd99..84ced4e5a7da 100644
--- a/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml
+++ b/Documentation/devicetree/bindings/iio/pressure/honeywell,mprls0025pa.yaml
@@ -42,6 +42,10 @@ properties:
maxItems: 1

interrupts:
+ description:
+ Optional interrupt for indicating End-of-conversion.
+ If not present, the driver loops for a while until the received status
+ byte indicates correct measurement.
maxItems: 1

reset-gpios:
@@ -65,6 +69,7 @@ properties:
1 - A, 10% to 90% of 2^24 (1677722 .. 15099494)
2 - B, 2.5% to 22.5% of 2^24 (419430 .. 3774874)
3 - C, 20% to 80% of 2^24 (3355443 .. 13421773)
+ enum: [1, 2, 3]
$ref: /schemas/types.yaml#/definitions/uint32

vdd-supply:
@@ -93,7 +98,7 @@ examples:
reg = <0x18>;
reset-gpios = <&gpio3 19 GPIO_ACTIVE_HIGH>;
interrupt-parent = <&gpio3>;
- interrupts = <21 IRQ_TYPE_EDGE_FALLING>;
+ interrupts = <21 IRQ_TYPE_EDGE_RISING>;
honeywell,pmin-pascal = <0>;
honeywell,pmax-pascal = <172369>;
honeywell,transfer-function = <1>;
--
2.41.0