Re: [PATCH v2] iio: bmp280: fix eoc interrupt usage

From: Andy Shevchenko
Date: Thu Oct 19 2023 - 12:54:42 EST


On Thu, Oct 19, 2023 at 06:22:09PM +0200, Andreas Klinger wrote:
> Only the bmp085 can have an End-Of-Conversion (EOC) interrupt. But the
> bmp085 and bmp180 share the same chip id. Therefore it's necessary to
> distinguish the case in which the interrupt is set.
>
> Fix the if statement so that only when the interrupt is set and the chip
> id is recognized the interrupt is requested.
>
> This bug exists since the support of EOC interrupt was introduced.

> Fixes: aae953949651 ("iio: pressure: bmp280: add support for BMP085 EOC interrupt")

As Jonathan already commented, this is part of a tag block below...

> Also add a link to bmp085 datasheet for reference.
>

...somewhere here.

> Suggested-by: Sergei Korolev <dssoftsk@xxxxxxxxx>
> Reviewed-by: Linus Walleij <linus.walleij@xxxxxxxxxx>
> Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx>
> ---
> v1 -> v2: Remove extra space (seen by Andy)


And seems Jonathan mentioned that this is already fixed in his tree.
Did I understand that correctly?

--
With Best Regards,
Andy Shevchenko