Re: [PATCH v4 3/4] dt-bindings: arm: Add new compatible for smc/hvc transport for SCMI

From: Nikunj Kela
Date: Thu Oct 05 2023 - 17:52:00 EST



On 10/4/2023 8:53 AM, Sudeep Holla wrote:
On Tue, Oct 03, 2023 at 08:59:45AM -0700, Nikunj Kela wrote:
On 10/3/2023 3:44 AM, Sudeep Holla wrote:
On Mon, Sep 11, 2023 at 12:43:58PM -0700, Nikunj Kela wrote:
Introduce compatible "qcom,scmi-hvc-shmem" for SCMI smc/hvc
transport channel for Qualcomm virtual platforms.
The compatible mandates a shared memory channel.

Signed-off-by: Nikunj Kela <quic_nkela@xxxxxxxxxxx>
Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx>
---
.../devicetree/bindings/firmware/arm,scmi.yaml | 12 ++++++++++++
1 file changed, 12 insertions(+)

diff --git a/Documentation/devicetree/bindings/firmware/arm,scmi.yaml b/Documentation/devicetree/bindings/firmware/arm,scmi.yaml
index 8d54ea768d38..4090240f45b1 100644
--- a/Documentation/devicetree/bindings/firmware/arm,scmi.yaml
+++ b/Documentation/devicetree/bindings/firmware/arm,scmi.yaml
@@ -45,6 +45,9 @@ properties:
- description: SCMI compliant firmware with OP-TEE transport
items:
- const: linaro,scmi-optee
+ - description: SCMI compliant firmware with Qualcomm hvc/shmem transport
+ items:
+ - const: qcom,scmi-hvc-shmem
Can it be simply "qcom,scmi-smc" for 2 reasons ?
1. We don't support SMC/HVC without shmem, so what is your argument to add
'-shmem' in the compatible here ?
In our platforms, there are multiple ways to allocate memory. One is
preallocated shmem as used here, another is dynamically by hypervisor APIs.
shmem was to just to indicate it is preallocated.

Let us keep it without shmem. If it is dynamically allocated, you must not
need another compatible as you can check it at the runtime.

2. The exact conduit(SMC/HVC) used is detected runtime, so I prefer to keep
'-smc' instead of '-hvc' in the compatible just to avoid giving an illusion
that HVC is the conduit chosen here based on the compatible. It can be true
for other reason but I don't want to mislead here by using HVC.
IUUC, currently, conduit comes from PSCI dt node. We have been using smc for
PSCI but want to use hvc here. That being said, I am fine to explore if we
can change PSCI to use hvc too.

I think only OPTEE has explicit conduit other than PSCI and it is continued
for legacy/compatibility reasons IIUC and IIRC. Anything else depends on
the conduit used by PSCI to be consistent. So yes you need to use what the
PSCI conduit is and you don't need the extra information from the DT either
as new property or in the compatible.

Ok, will use conduit then. Thanks!