Re: [PATCH v2 -next 3/4] RISC-V: cacheflush: Initialize CBO variables on ACPI systems

From: Sunil V L
Date: Wed Oct 04 2023 - 00:22:39 EST


On Tue, Oct 03, 2023 at 02:50:02PM -0500, Samuel Holland wrote:
> On 2023-09-27 12:00 PM, Sunil V L wrote:
> > Using new interface to get the CBO block size information in RHCT,
> > initialize the variables on ACPI platforms.
> >
> > Signed-off-by: Sunil V L <sunilvl@xxxxxxxxxxxxxxxx>
> > ---
> > arch/riscv/mm/cacheflush.c | 37 +++++++++++++++++++++++++++++++------
> > 1 file changed, 31 insertions(+), 6 deletions(-)
> >
> > diff --git a/arch/riscv/mm/cacheflush.c b/arch/riscv/mm/cacheflush.c
> > index f1387272a551..8e59644e473c 100644
> > --- a/arch/riscv/mm/cacheflush.c
> > +++ b/arch/riscv/mm/cacheflush.c
> > @@ -3,7 +3,9 @@
> > * Copyright (C) 2017 SiFive
> > */
> >
> > +#include <linux/acpi.h>
> > #include <linux/of.h>
> > +#include <asm/acpi.h>
> > #include <asm/cacheflush.h>
> >
> > #ifdef CONFIG_SMP
> > @@ -124,15 +126,38 @@ void __init riscv_init_cbo_blocksizes(void)
> > unsigned long cbom_hartid, cboz_hartid;
> > u32 cbom_block_size = 0, cboz_block_size = 0;
> > struct device_node *node;
> > + struct acpi_table_header *rhct;
> > + acpi_status status;
> > + unsigned int cpu;
> > +
> > + if (!acpi_disabled) {
> > + status = acpi_get_table(ACPI_SIG_RHCT, 0, &rhct);
> > + if (ACPI_FAILURE(status))
> > + return;
> > + }
> >
> > - for_each_of_cpu_node(node) {
> > - /* set block-size for cbom and/or cboz extension if available */
> > - cbo_get_block_size(node, "riscv,cbom-block-size",
> > - &cbom_block_size, &cbom_hartid);
> > - cbo_get_block_size(node, "riscv,cboz-block-size",
> > - &cboz_block_size, &cboz_hartid);
> > + for_each_possible_cpu(cpu) {
> > + if (acpi_disabled) {
> > + node = of_cpu_device_node_get(cpu);
> > + if (!node) {
> > + pr_warn("Unable to find cpu node\n");
> > + continue;
> > + }
> > +
> > + /* set block-size for cbom and/or cboz extension if available */
> > + cbo_get_block_size(node, "riscv,cbom-block-size",
> > + &cbom_block_size, &cbom_hartid);
> > + cbo_get_block_size(node, "riscv,cboz-block-size",
> > + &cboz_block_size, &cboz_hartid);
>
> This leaks a reference to the device node.
>
Yep!. I missed of_node_put(). Let me add in next revision. Thanks!

> > + } else {
> > + acpi_get_cbo_block_size(rhct, cpu, &cbom_block_size,
> > + &cboz_block_size, NULL);
>
> This function loops through the whole RHCT already. Why do we need to call it
> for each CPU? Can't we just call it once, and have it do the same consistency
> checks as cbo_get_block_size()?
>
> In that case, the DT path could keep the for_each_of_cpu_node() loop.
>
I kept the same logic as DT. Basically, by passing the cpu node, we
will fetch the exact CPU's CBO property from RHCT. It is not clear to me
why we overwrite the same variable with value from another cpu and
whether we can return as soon as we get the CBO size for one CPU.

Drew, can we exit the loop if we get the CBO size for one CPU?

Thanks!
Sunil