Re: [PATCH v2 1/2] dt-bindings: i2c: Add custom properties for MAX7357/MAX7358

From: Krzysztof Kozlowski
Date: Thu Aug 31 2023 - 08:03:31 EST


On 31/08/2023 12:15, Naresh Solanki wrote:
> From: Patrick Rudolph <patrick.rudolph@xxxxxxxxxxxxx>
>
> Both chips have a configuration register to enable additional
> features. These features aren't enabled by default & its up to
> board designer to enable the same.
>
> Add booleans for:
> - maxim,isolate-stuck-channel
> - maxim,send-flush-out-sequence
> - maxim,preconnection-wiggle-test-enable
>
> Signed-off-by: Patrick Rudolph <patrick.rudolph@xxxxxxxxxxxxx>
> Signed-off-by: Naresh Solanki <Naresh.Solanki@xxxxxxxxxxxxx>

Subject: still did not improve. You waited exactly 30 minutes for my
feedback after sending your response.



> ---
> Changes in V2:
> - Update properties.
> ---
> .../bindings/i2c/i2c-mux-pca954x.yaml | 31 +++++++++++++++++++
> 1 file changed, 31 insertions(+)
>
> diff --git a/Documentation/devicetree/bindings/i2c/i2c-mux-pca954x.yaml b/Documentation/devicetree/bindings/i2c/i2c-mux-pca954x.yaml
> index 2d7bb998b0e9..fa73eadfdf7b 100644
> --- a/Documentation/devicetree/bindings/i2c/i2c-mux-pca954x.yaml
> +++ b/Documentation/devicetree/bindings/i2c/i2c-mux-pca954x.yaml
> @@ -71,6 +71,23 @@ properties:
> description: A voltage regulator supplying power to the chip. On PCA9846
> the regulator supplies power to VDD2 (core logic) and optionally to VDD1.
>
> + maxim,isolate-stuck-channel:
> + type: boolean
> + description: Allows to use non faulty channels while a stuck channel is
> + isolated from the upstream bus. If not set all channels are isolated from
> + the upstream bus until the fault is cleared.

Nothing improved here. As I said, please provide arguments or drop this
property.

> +
> + maxim,send-flush-out-sequence:
> + type: boolean
> + description: Send a flush-out sequence to stuck auxiliary buses
> + automatically after a stuck channel is being detected.

Ditto

> +
> + maxim,preconnection-wiggle-test-enable:
> + type: boolean
> + description: Send a STOP condition to the auxiliary buses when the switch
> + register activates a channel to detect a stuck high fault. On fault the
> + channel is isolated from the upstream bus.

Ditto


Best regards,
Krzysztof