[PATCH 2/8] AMR: dts: imx6ull-colibri: drop incorrect regulator regulator-type

From: Krzysztof Kozlowski
Date: Wed Jul 26 2023 - 03:06:05 EST


regulator-fixed-clock does not take "regulator-type" property:

imx6ull-colibri-iris-v2.dtb: regulator-eth-phy: Unevaluated properties are not allowed ('regulator-type' was unexpected)

Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx>
---
arch/arm/boot/dts/nxp/imx/imx6ull-colibri.dtsi | 1 -
1 file changed, 1 deletion(-)

diff --git a/arch/arm/boot/dts/nxp/imx/imx6ull-colibri.dtsi b/arch/arm/boot/dts/nxp/imx/imx6ull-colibri.dtsi
index fde8a19aac0f..ec3c1e7301f4 100644
--- a/arch/arm/boot/dts/nxp/imx/imx6ull-colibri.dtsi
+++ b/arch/arm/boot/dts/nxp/imx/imx6ull-colibri.dtsi
@@ -102,7 +102,6 @@ reg_eth_phy: regulator-eth-phy {
regulator-min-microvolt = <3300000>;
regulator-max-microvolt = <3300000>;
regulator-name = "+V3.3_ETH";
- regulator-type = "voltage";
vin-supply = <&reg_module_3v3>;
clocks = <&clks IMX6UL_CLK_ENET2_REF_125M>;
startup-delay-us = <150000>;
--
2.34.1