Re: [PATCH 1/3] watchdog: make Siemens Simatic watchdog driver default on platform

From: Henning Schild
Date: Wed Jul 19 2023 - 03:21:00 EST


Am Tue, 18 Jul 2023 08:07:52 -0700
schrieb Guenter Roeck <linux@xxxxxxxxxxxx>:

> On Tue, Jul 18, 2023 at 12:52:11PM +0200, Henning Schild wrote:
> > If a user did choose to enable Siemens Simatic platform support they
> > likely want that driver to be enabled without having to flip more
> > config switches. So we make the watchdog driver config switch
> > default to the platform driver switches value.
> >
> > Signed-off-by: Henning Schild <henning.schild@xxxxxxxxxxx>
> > ---
> > drivers/watchdog/Kconfig | 1 +
> > 1 file changed, 1 insertion(+)
> >
> > diff --git a/drivers/watchdog/Kconfig b/drivers/watchdog/Kconfig
> > index ee97d89dfc11..ccdbd1109a32 100644
> > --- a/drivers/watchdog/Kconfig
> > +++ b/drivers/watchdog/Kconfig
> > @@ -1681,6 +1681,7 @@ config NIC7018_WDT
> > config SIEMENS_SIMATIC_IPC_WDT
> > tristate "Siemens Simatic IPC Watchdog"
> > depends on SIEMENS_SIMATIC_IPC
> > + default SIEMENS_SIMATIC_IPC
>
> Why not just "default y" ? That does the same (it will be set to m if
> SIEMENS_SIMATIC_IPC=m) without the complexity.

I see. Thanks! In that case i will go for "default y" and not "default
m" which i wrote about in the other mail.

Henning