Re: [PATCH 2/2] Input: exc3000 - Support power supply regulators

From: Dmitry Torokhov
Date: Wed Jul 05 2023 - 17:50:10 EST


Hi Mike,

On Mon, Jul 03, 2023 at 10:45:36AM +0200, Mike Looijmans wrote:
> Add power supply regulator support to the exc3000 devices.
>
> Signed-off-by: Mike Looijmans <mike.looijmans@xxxxxxxx>
>
> ---
>
> drivers/input/touchscreen/exc3000.c | 7 +++++++
> 1 file changed, 7 insertions(+)
>
> diff --git a/drivers/input/touchscreen/exc3000.c b/drivers/input/touchscreen/exc3000.c
> index 4af4c1e5d0da..3e50af8a4a2d 100644
> --- a/drivers/input/touchscreen/exc3000.c
> +++ b/drivers/input/touchscreen/exc3000.c
> @@ -18,6 +18,7 @@
> #include <linux/interrupt.h>
> #include <linux/module.h>
> #include <linux/of.h>
> +#include <linux/regulator/consumer.h>
> #include <linux/sizes.h>
> #include <linux/timer.h>
> #include <asm/unaligned.h>
> @@ -360,6 +361,12 @@ static int exc3000_probe(struct i2c_client *client)
> if (IS_ERR(data->reset))
> return PTR_ERR(data->reset);
>
> + /* For proper reset sequence, enable power while reset asserted */
> + error = devm_regulator_get_enable_optional(&client->dev, "vdd");
> + if (error && error != -ENODEV)
> + dev_err_probe(&client->dev, error,
> + "failed to request vdd regulator\n");


If there is a regulator described in the firmware we should not continue
with initializing the device if we fail to grab/enable it. Think about
what happens if you get -EPROBE_DEFER here. You should return here.

Also, why are you using the _optional() variant? VDD is not an optional
for the controller. regulator_get_optional() is needed when you need to
alter the behavior of the device/driver depending on the presence of an
optional supply, whereas here it should work fine with a sub supply that
will be created if you simply call devm_regulator_get_enable() and there
is not regulator mentioned in DT/ACPI for the board.

Thanks.

--
Dmitry