Re: [PATCH 1/1] thermal: sysfs: avoid actual readings from sysfs

From: Daniel Lezcano
Date: Fri Jun 30 2023 - 06:11:36 EST



Hi Rafael,

On 30/06/2023 10:16, Rafael J. Wysocki wrote:
On Wed, Jun 28, 2023 at 11:10 PM Eduardo Valentin <evalenti@xxxxxxxxxx> wrote:

[ ... ]

So what about adding a new zone attribute that can be used to specify
the preferred caching time for the temperature?

That is, if the time interval between two consecutive updates of the
cached temperature value is less than the value of the new attribute,
the cached temperature value will be returned by "temp". Otherwise,
it will cause the sensor to be read and the value obtained from it
will be returned to user space and cached.

If the value of the new attribute is 0, everything will work as it
does now (which will also need to be the default behavior).

I'm still not convinced about the feature.

Eduardo provided some numbers but they seem based on the characteristics of the I2C, not to a real use case. Eduardo?

Before adding more complexity in the thermal framework and yet another sysfs entry, it would be interesting to have an experiment and show the impact of both configurations, not from a timing point of view but with a temperature mitigation accuracy.

Without a real use case, this feature does make really sense IMO.


--
<http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs

Follow Linaro: <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog