Re: [PATCH v3 1/4] dt-bindings: remoteproc: st,stm32-rproc: Rework reset declarations

From: Krzysztof Kozlowski
Date: Sun May 14 2023 - 05:40:36 EST


On 12/05/2023 11:39, Arnaud Pouliquen wrote:
> With the introduction of the SCMI (System Control and Management
> Interface), it is now possible to use the SCMI to handle the
> hold boot instead of a dedicated SMC call.
>
> As consequence two configurations are possible:
> - without SCMI server on OP-TEE:
> use the Linux rcc reset service and use syscon for the MCU hold boot
> - With SCMI server on OP-TEE:
> use the SCMI reset service for both the MCU reset and the MCU hold boot.
>

Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx>

Best regards,