[PATCH v4 2/6] thermal: qcom: tsens-v0_1: Fix mdm9607 slope values

From: Stephan Gerhold
Date: Mon May 08 2023 - 09:37:34 EST


According to the msm-3.18 vendor kernel from Qualcomm [1], mdm9607 uses
a non-standard slope value of 3000 (instead of 3200) for all sensors.
Fill it properly similar to the 8939 code added recently.

[1]: https://git.codelinaro.org/clo/la/kernel/msm-3.18/-/blob/LE.UM.4.3.2.r1-04200-9x07/arch/arm/boot/dts/qcom/mdm9607.dtsi#L875

Fixes: a2149ab815fc ("thermal/drivers/qcom/tsens-v0_1: Add support for MDM9607")
Reviewed-by: Konrad Dybcio <konrad.dybcio@xxxxxxxxxx>
Signed-off-by: Stephan Gerhold <stephan.gerhold@xxxxxxxxxxxxxxx>
---
drivers/thermal/qcom/tsens-v0_1.c | 24 +++++++++++++++++-------
1 file changed, 17 insertions(+), 7 deletions(-)

diff --git a/drivers/thermal/qcom/tsens-v0_1.c b/drivers/thermal/qcom/tsens-v0_1.c
index 106d26076e3f..1b454de3928d 100644
--- a/drivers/thermal/qcom/tsens-v0_1.c
+++ b/drivers/thermal/qcom/tsens-v0_1.c
@@ -222,6 +222,16 @@ static int __init init_8939(struct tsens_priv *priv) {
return init_common(priv);
}

+static int __init init_9607(struct tsens_priv *priv)
+{
+ int i;
+
+ for (i = 0; i < priv->num_sensors; ++i)
+ priv->sensor[i].slope = 3000;
+
+ return init_common(priv);
+}
+
/* v0.1: 8916, 8939, 8974, 9607 */

static struct tsens_features tsens_v0_1_feat = {
@@ -271,12 +281,6 @@ static const struct reg_field tsens_v0_1_regfields[MAX_REGFIELDS] = {
[TRDY] = REG_FIELD(TM_TRDY_OFF, 0, 0),
};

-static const struct tsens_ops ops_v0_1 = {
- .init = init_common,
- .calibrate = tsens_calibrate_common,
- .get_temp = get_temp_common,
-};
-
static const struct tsens_ops ops_8916 = {
.init = init_common,
.calibrate = calibrate_8916,
@@ -320,9 +324,15 @@ struct tsens_plat_data data_8974 = {
.fields = tsens_v0_1_regfields,
};

+static const struct tsens_ops ops_9607 = {
+ .init = init_9607,
+ .calibrate = tsens_calibrate_common,
+ .get_temp = get_temp_common,
+};
+
struct tsens_plat_data data_9607 = {
.num_sensors = 5,
- .ops = &ops_v0_1,
+ .ops = &ops_9607,
.feat = &tsens_v0_1_feat,
.fields = tsens_v0_1_regfields,
};

--
2.30.2