Re: [PATCH 3/6] phy: qcom-qmp-combo: fix sc8180x reset

From: Dmitry Baryshkov
Date: Sat Nov 12 2022 - 02:51:28 EST


On 11/11/2022 11:42, Johan Hovold wrote:
The SC8180X has two resets but the DP configuration erroneously
described only one.

In case the DP part of the PHY is initialised before the USB part (e.g.
depending on probe order), then only the first reset would be asserted.

Fixes: 1633802cd4ac ("phy: qcom: qmp: Add SC8180x USB/DP combo")
Cc: stable@xxxxxxxxxxxxxxx # 5.15
Signed-off-by: Johan Hovold <johan+linaro@xxxxxxxxxx>
---
drivers/phy/qualcomm/phy-qcom-qmp-combo.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)


Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx>

--
With best wishes
Dmitry