Re: [PATCH 1/1] net: fec: using page pool to manage RX buffers

From: Andrew Lunn
Date: Fri Sep 30 2022 - 15:52:34 EST


On Fri, Sep 30, 2022 at 02:37:51PM -0500, Shenwei Wang wrote:
> This patch optimizes the RX buffer management by using the page
> pool. The purpose for this change is to prepare for the following
> XDP support. The current driver uses one frame per page for easy
> management.
>
> The following are the comparing result between page pool implementation
> and the original implementation (non page pool).
>
> --- Page Pool implementation ----
>
> shenwei@5810:~$ iperf -c 10.81.16.245 -w 2m -i 1
> ------------------------------------------------------------
> Client connecting to 10.81.16.245, TCP port 5001
> TCP window size: 416 KByte (WARNING: requested 1.91 MByte)
> ------------------------------------------------------------
> [ 1] local 10.81.17.20 port 43204 connected with 10.81.16.245 port 5001
> [ ID] Interval Transfer Bandwidth
> [ 1] 0.0000-1.0000 sec 111 MBytes 933 Mbits/sec
> [ 1] 1.0000-2.0000 sec 111 MBytes 934 Mbits/sec
> [ 1] 2.0000-3.0000 sec 112 MBytes 935 Mbits/sec
> [ 1] 3.0000-4.0000 sec 111 MBytes 933 Mbits/sec
> [ 1] 4.0000-5.0000 sec 111 MBytes 934 Mbits/sec
> [ 1] 5.0000-6.0000 sec 111 MBytes 933 Mbits/sec
> [ 1] 6.0000-7.0000 sec 111 MBytes 931 Mbits/sec
> [ 1] 7.0000-8.0000 sec 112 MBytes 935 Mbits/sec
> [ 1] 8.0000-9.0000 sec 111 MBytes 933 Mbits/sec
> [ 1] 9.0000-10.0000 sec 112 MBytes 935 Mbits/sec
> [ 1] 0.0000-10.0077 sec 1.09 GBytes 933 Mbits/sec
>
> --- Non Page Pool implementation ----
>
> shenwei@5810:~$ iperf -c 10.81.16.245 -w 2m -i 1
> ------------------------------------------------------------
> Client connecting to 10.81.16.245, TCP port 5001
> TCP window size: 416 KByte (WARNING: requested 1.91 MByte)
> ------------------------------------------------------------
> [ 1] local 10.81.17.20 port 49154 connected with 10.81.16.245 port 5001
> [ ID] Interval Transfer Bandwidth
> [ 1] 0.0000-1.0000 sec 104 MBytes 868 Mbits/sec
> [ 1] 1.0000-2.0000 sec 105 MBytes 878 Mbits/sec
> [ 1] 2.0000-3.0000 sec 105 MBytes 881 Mbits/sec
> [ 1] 3.0000-4.0000 sec 105 MBytes 879 Mbits/sec
> [ 1] 4.0000-5.0000 sec 105 MBytes 878 Mbits/sec
> [ 1] 5.0000-6.0000 sec 105 MBytes 878 Mbits/sec
> [ 1] 6.0000-7.0000 sec 104 MBytes 875 Mbits/sec
> [ 1] 7.0000-8.0000 sec 104 MBytes 875 Mbits/sec
> [ 1] 8.0000-9.0000 sec 104 MBytes 873 Mbits/sec
> [ 1] 9.0000-10.0000 sec 104 MBytes 875 Mbits/sec
> [ 1] 0.0000-10.0073 sec 1.02 GBytes 875 Mbits/sec

What SoC? As i keep saying, the FEC is used in a lot of different
SoCs, and you need to show this does not cause any regressions in the
older SoCs. There are probably a lot more imx5 and imx6 devices out in
the wild than imx8, which is what i guess you are testing on. Mainline
needs to work well on them all, even if NXP no longer cares about the
older Socs.

Andrew