[PATCH] regulator: qcom-rpmh: Implement get_optimum_mode(), not set_load()

From: Douglas Anderson
Date: Tue Jul 26 2022 - 13:21:00 EST


Since we don't actually pass the load to the firmware, switch to using
get_optimum_mode() instead of open-coding it.

This is intended to have no effect other than cleanup.

Signed-off-by: Douglas Anderson <dianders@xxxxxxxxxxxx>
---

drivers/regulator/qcom-rpmh-regulator.c | 17 ++++++++---------
1 file changed, 8 insertions(+), 9 deletions(-)

diff --git a/drivers/regulator/qcom-rpmh-regulator.c b/drivers/regulator/qcom-rpmh-regulator.c
index 561de6b2e6e3..b2debde79361 100644
--- a/drivers/regulator/qcom-rpmh-regulator.c
+++ b/drivers/regulator/qcom-rpmh-regulator.c
@@ -306,9 +306,10 @@ static unsigned int rpmh_regulator_vrm_get_mode(struct regulator_dev *rdev)
}

/**
- * rpmh_regulator_vrm_set_load() - set the regulator mode based upon the load
- * current requested
+ * rpmh_regulator_vrm_get_optimum_mode() - get the mode based on the load
* @rdev: Regulator device pointer for the rpmh-regulator
+ * @input_uV: Input voltage
+ * @output_uV: Output voltage
* @load_uA: Aggregated load current in microamps
*
* This function is used in the regulator_ops for VRM type RPMh regulator
@@ -316,17 +317,15 @@ static unsigned int rpmh_regulator_vrm_get_mode(struct regulator_dev *rdev)
*
* Return: 0 on success, errno on failure
*/
-static int rpmh_regulator_vrm_set_load(struct regulator_dev *rdev, int load_uA)
+static unsigned int rpmh_regulator_vrm_get_optimum_mode(
+ struct regulator_dev *rdev, int input_uV, int output_uV, int load_uA)
{
struct rpmh_vreg *vreg = rdev_get_drvdata(rdev);
- unsigned int mode;

if (load_uA >= vreg->hw_data->hpm_min_load_uA)
- mode = REGULATOR_MODE_NORMAL;
+ return REGULATOR_MODE_NORMAL;
else
- mode = REGULATOR_MODE_IDLE;
-
- return rpmh_regulator_vrm_set_mode(rdev, mode);
+ return REGULATOR_MODE_IDLE;
}

static int rpmh_regulator_vrm_set_bypass(struct regulator_dev *rdev,
@@ -375,7 +374,7 @@ static const struct regulator_ops rpmh_regulator_vrm_drms_ops = {
.list_voltage = regulator_list_voltage_linear_range,
.set_mode = rpmh_regulator_vrm_set_mode,
.get_mode = rpmh_regulator_vrm_get_mode,
- .set_load = rpmh_regulator_vrm_set_load,
+ .get_optimum_mode = rpmh_regulator_vrm_get_optimum_mode,
};

static const struct regulator_ops rpmh_regulator_vrm_bypass_ops = {
--
2.37.1.359.gd136c6c3e2-goog