Re: [PATCH] dt-bindings: arm: mediatek: mmsys: refine power and gce properties

From: Krzysztof Kozlowski
Date: Fri Apr 29 2022 - 01:56:06 EST


On 29/04/2022 06:10, Jason-JH Lin wrote:
> Yes, we cannot have infinite number for this, but we can use not only
> one mbox channel for one mmsys.
>
> Its maximum number is equal to GCE HW thread number.
> The maximum number in mt8195 is 24 and mt8173 is 16.
>
> But we currently using 1.
> So I'm not sure if I need to set the maxItems for this?

Yes. 24 for mt8195 and 16 for mt8173.

>
>>
>>> description:
>>> - Using mailbox to communicate with GCE, it should have this
>>> - property and list of phandle, mailbox specifiers. See
>>> - Documentation/devicetree/bindings/mailbox/mtk-gce.txt for
>>> details.
>>> - $ref: /schemas/types.yaml#/definitions/phandle-array
>>> + If using mailbox to communicate with GCE, it should have
>>> this
>>> + property. GCE will help configure the hardware settings for
>>> the
>>> + current mmsys data pipeline.
>>>
>>> mediatek,gce-client-reg:
>>> - description:
>>> - The register of client driver can be configured by gce with
>>> 4 arguments
>>> - defined in this property, such as phandle of gce, subsys id,
>>> - register offset and size.
>>> - Each subsys id is mapping to a base address of display
>>> function blocks
>>> - register which is defined in the gce header
>>> - include/dt-bindings/gce/<chip>-gce.h.
>>> - $ref: /schemas/types.yaml#/definitions/phandle-array
>>
>> Why removing ref? Does your binding work after such change?
>
> I removed it unexpectedly, I'll add it back.

Just be sure you test it before submitting...


Best regards,