[PATCH 2/2] EDAC: synopsys: re-enable the interrupts in intr_handler for V3.X Synopsys EDAC DDR

From: Sherry Sun
Date: Fri Mar 18 2022 - 07:20:44 EST


Since zynqmp_get_error_info() is called during CE/UE interrupt, at the
end of zynqmp_get_error_info(), it wirtes 0 to ECC_CLR_OFST, which cause
the CE/UE interrupts of V3.X Synopsys EDAC DDR been disabled, then the
interrupt handler will be called only once, so need to re-enable the
interrupts at the end of intr_handler for V3.X Synopsys EDAC DDR.

Signed-off-by: Sherry Sun <sherry.sun@xxxxxxx>
---
drivers/edac/synopsys_edac.c | 4 ++++
1 file changed, 4 insertions(+)

diff --git a/drivers/edac/synopsys_edac.c b/drivers/edac/synopsys_edac.c
index 1b630f0be119..3a1db34a8546 100644
--- a/drivers/edac/synopsys_edac.c
+++ b/drivers/edac/synopsys_edac.c
@@ -521,6 +521,8 @@ static void handle_error(struct mem_ctl_info *mci, struct synps_ecc_status *p)
memset(p, 0, sizeof(*p));
}

+static void enable_intr(struct synps_edac_priv *priv);
+
/**
* intr_handler - Interrupt Handler for ECC interrupts.
* @irq: IRQ number.
@@ -562,6 +564,8 @@ static irqreturn_t intr_handler(int irq, void *dev_id)
/* v3.0 of the controller does not have this register */
if (!(priv->p_data->quirks & DDR_ECC_INTR_SELF_CLEAR))
writel(regval, priv->baseaddr + DDR_QOS_IRQ_STAT_OFST);
+ else
+ enable_intr(priv);
return IRQ_HANDLED;
}

--
2.17.1