Re: [PATCH] perf arm-spe: Use advertised caps/min_interval as default sample_period

From: Leo Yan
Date: Tue Feb 22 2022 - 20:14:53 EST


On Mon, Feb 21, 2022 at 05:10:42PM +0000, German Gomez wrote:
> When recording SPE traces, the default sample_period is currently being
> set to 1 in the perf_event_attr fields, instead of the value advertised
> in '/sys/devices/arm_spe_0/caps/min_interval':
>
> Before:
>
> $ perf record -e arm_spe// -vv -- sleep 1
> [...]
> { sample_period, sample_freq } 1
> [...]
>
> Use the value from the above sysfs location as a more sensible default
> (it was already being read, but the value not being used)
>
> After:
>
> $ perf record -e arm_spe// -vv -- sleep 1
> [...]
> { sample_period, sample_freq } 1024
> [...]
>
> Signed-off-by: German Gomez <german.gomez@xxxxxxx>

The change looks good to me: