Re: [PATCH v2 3/3] clocksource/drivers/exynos_mct: bump up number of local timer

From: Krzysztof Kozlowski
Date: Sun Feb 20 2022 - 12:34:18 EST


On 20/02/2022 17:59, Alim Akhtar wrote:
>
>
>> -----Original Message-----
>> From: Krzysztof Kozlowski [mailto:krzysztof.kozlowski@xxxxxxxxxxxxx]
>> Sent: Sunday, February 20, 2022 9:03 PM
>> To: Alim Akhtar <alim.akhtar@xxxxxxxxxxx>; linux-arm-
>> kernel@xxxxxxxxxxxxxxxxxxx; linux-kernel@xxxxxxxxxxxxxxx
>> Cc: linux-samsung-soc@xxxxxxxxxxxxxxx; daniel.lezcano@xxxxxxxxxx;
>> tglx@xxxxxxxxxxxxx; pankaj.dubey@xxxxxxxxxxx;
>> m.szyprowski@xxxxxxxxxxx
>> Subject: Re: [PATCH v2 3/3] clocksource/drivers/exynos_mct: bump up
>> number of local timer
>>
>> On 20/02/2022 14:38, Alim Akhtar wrote:
>>> As per the dt binding, maximum number of local timer can be up to 16.
>>> Increase the array size of the _name_ variable which holds the number
>>> of local timer name per CPU to reflect the binding. While at it,
>>> change the magic number to a meaningful macro.
>>
>> This still does not make sense. Let's say you have 16 local timers, so why the
>> name of clock event device should be maximum 16? How are these related?
>>
> As you rightly commented on v1 and it is mainly for "mct_tick%d" with number of local timers and
> local timer is per cpu. With increase in cpu number, name[10] restrict the scalability.
> So either we can change to 11, or use some reference (as local timer number in this patch).
> Let me know your thought on this.

There could be some reference, like dedicated define. However length is
not directly related to the number of local irqs, but only number of
digits in decimal representation. If MCT_NR_LOCAL_TIMERS is increased
from 12 to 20, or from 20 to 80, the length should stay the same.

I propose to keep it at 11 and add a comment that length of the name
must be adjusted if number of interrupts grow over two digits.

Best regards,
Krzysztof