[PATCH v3 3/3] ABI: testing: sysfs-class-power: Adds "Long Life" entry

From: Ricardo Rivera-Matos
Date: Mon Feb 14 2022 - 19:08:39 EST


Adds a brief desciption of the "Long Life" charge type and adds "Long Life"
to the list of valid values.

Signed-off-by: Ricardo Rivera-Matos <rriveram@xxxxxxxxxxxxxxxxxxxxx>
---
Documentation/ABI/testing/sysfs-class-power | 11 ++++++-----
1 file changed, 6 insertions(+), 5 deletions(-)

diff --git a/Documentation/ABI/testing/sysfs-class-power b/Documentation/ABI/testing/sysfs-class-power
index 8e3bf1aa6268..b304fa9c1482 100644
--- a/Documentation/ABI/testing/sysfs-class-power
+++ b/Documentation/ABI/testing/sysfs-class-power
@@ -380,16 +380,17 @@ Description:
algorithm to adjust the charge rate dynamically, without
any user configuration required. "Custom" means that the charger
uses the charge_control_* properties as configuration for some
- different algorithm. "Bypass" means the charger bypasses the
- charging path around the integrated converter allowing for a
- "smart" wall adaptor to perform the power conversion
- externally.
+ different algorithm. "Long Life" means the charger reduces its
+ charging rate in order to prolong the battery health. "Bypass"
+ means the charger bypasses the charging path around the
+ integrated converter allowing for a "smart" wall adaptor to
+ perform the power conversion externally.

Access: Read, Write

Valid values:
"Unknown", "N/A", "Trickle", "Fast", "Standard",
- "Adaptive", "Custom", "Bypass"
+ "Adaptive", "Custom", "Long Life", "Bypass"

What: /sys/class/power_supply/<supply_name>/charge_term_current
Date: July 2014
--
2.25.1