[PATCH net] can: j1939: j1939_xtp_rx_dat_one(): fix rxtimer value between consecutive TP.DT to 750ms

From: Zhang Changzhong
Date: Tue Jul 06 2021 - 06:54:04 EST


For receive side, the max time interval between two consecutive TP.DT
should be 750ms.

Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <zhangchangzhong@xxxxxxxxxx>
---
net/can/j1939/transport.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index c3946c3..4113229 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1869,7 +1869,7 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
if (!session->transmission)
j1939_tp_schedule_txtimer(session, 0);
} else {
- j1939_tp_set_rxtimeout(session, 250);
+ j1939_tp_set_rxtimeout(session, 750);
}
session->last_cmd = 0xff;
consume_skb(se_skb);
--
2.9.5