[RFCv1 0/8] Meson-8b and Meson-gxbb USB phy code re-structure

From: Anand Moon
Date: Thu Jun 17 2021 - 15:42:40 EST


On Odroid C1+ and Odroid C2 USB feature is broken
this code changes are just re-structure the code so that
proper callback function execute in proper order.

Code changes losely based on phy-meson-gxl-usb2.c

Initially if we connect USB HDD at initial boot it get detected.
but after that usb hotplug of USB HDD is broken.
I did not observe and USB debug events messages to trace the root cause.

Another issue I observed is increase of USB interrupts event
even if there is not much activity on USB ports.
I tried some clk changes but it did not workout for me.

$ cat /proc/interrupts | grep usb
45: 0 0 0 0 GICv2 62 Level c9000000.usb, dwc2_hsotg:usb1
46: 17488032 0 0 0 GICv2 63 Level c9100000.usb, dwc2_hsotg:usb2

Thanks
-Anand

Anand Moon (8):
phy: amlogic: meson8b-usb2: Use clock bulk to get clocks for phy
phy: amlogic: meson8b-usb2: Use phy init callback function
phy: amlogic: meson8b-usb2: Use phy exit callback function
phy: amlogic: meson8b-usb2: Use phy set_mode callback function
phy: amlogic: meson8b-usb2: Reorder phy poweroff callback function
phy: amlogic: meson8b-usb2: Use phy reset callback function
phy: amlogic: meson8b-usb2: Power off the PHY by putting it into reset
mode.
phy: amlogic: meson8b-usb2: don't log an error on -EPROBE_DEFER

drivers/phy/amlogic/phy-meson8b-usb2.c | 159 +++++++++++++++++--------
1 file changed, 109 insertions(+), 50 deletions(-)

--