Re: [PATCH v2] IMA: support for duplicate data measurement

From: Tushar Sugandhi
Date: Wed Feb 17 2021 - 13:54:24 EST


Thanks for the feedback Mimi.
Appreciate it.

On 2021-02-17 7:03 a.m., Mimi Zohar wrote:
Hi Tushar,

The Subject line could be improved. Perhaps something like - "IMA:
support for duplicate measurement records"

Will do.

On Tue, 2021-02-16 at 18:46 -0800, Tushar Sugandhi wrote:
IMA does not measure duplicate data since TPM extend is a very expensive
operation. However, in some cases, the measurement of duplicate data
is necessary to accurately determine the current state of the system.
Eg, SELinux state changing from 'audit', to 'enforcing', and back to
'audit' again. In this example, currently, IMA will not measure the
last state change to 'audit'. This limits the ability of attestation
services to accurately determine the current state of the measurements
on the system.

This patch description is written from your specific usecase
perspective, but it impacts file and buffer data measurements as well,
not only critical data measurements. In all of these situations, with
this patch a new measurement record is added/appended to the
measurement list. Please re-write the patch description making it more
generic.

For example, I would start with something like, "IMA does not include
duplicate file, buffer or critical data measurement records ..."

Agreed.
I will generalize the description further and send the v3 for review.

Thanks,
Tushar

thanks,

Mimi


Update ima_add_template_entry() to support measurement of duplicate
data, driven by a Kconfig option - IMA_DISABLE_HTABLE.

Signed-off-by: Tushar Sugandhi <tusharsu@xxxxxxxxxxxxxxxxxxx>