[PATCH v2 1/9] mfd: axp20x: Mark AXP20X_VBUS_IPSOUT_MGMT as volatile

From: Samuel Holland
Date: Sat Jan 04 2020 - 20:24:20 EST


On AXP288 and newer PMICs, bit 7 of AXP20X_VBUS_IPSOUT_MGMT can be set
to prevent using the VBUS input. However, when the VBUS unplugged and
plugged back in, the bit automatically resets to zero.

We need to set the register as volatile to prevent regmap from caching
that bit. Otherwise, regcache will think the bit is already set and not
write the register.

Fixes: cd53216625a0 ("mfd: axp20x: Fix axp288 volatile ranges")
Cc: stable@xxxxxxxxxxxxxxx
Signed-off-by: Samuel Holland <samuel@xxxxxxxxxxxx>
---
drivers/mfd/axp20x.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/mfd/axp20x.c b/drivers/mfd/axp20x.c
index a4aaadaa0cb0..aa59496e4376 100644
--- a/drivers/mfd/axp20x.c
+++ b/drivers/mfd/axp20x.c
@@ -126,7 +126,7 @@ static const struct regmap_range axp288_writeable_ranges[] = {
static const struct regmap_range axp288_volatile_ranges[] = {
regmap_reg_range(AXP20X_PWR_INPUT_STATUS, AXP288_POWER_REASON),
regmap_reg_range(AXP288_BC_GLOBAL, AXP288_BC_GLOBAL),
- regmap_reg_range(AXP288_BC_DET_STAT, AXP288_BC_DET_STAT),
+ regmap_reg_range(AXP288_BC_DET_STAT, AXP20X_VBUS_IPSOUT_MGMT),
regmap_reg_range(AXP20X_CHRG_BAK_CTRL, AXP20X_CHRG_BAK_CTRL),
regmap_reg_range(AXP20X_IRQ1_EN, AXP20X_IPSOUT_V_HIGH_L),
regmap_reg_range(AXP20X_TIMER_CTRL, AXP20X_TIMER_CTRL),
--
2.23.0