[PATCH v2 3/6] dt: bindings: lm3692x: Add ti,brightness-mapping-exponential property

From: Guido GÃnther
Date: Wed Dec 25 2019 - 06:07:33 EST


This allows to select exponential brightness mode instead of the default
linear mode.

Signed-off-by: Guido GÃnther <agx@xxxxxxxxxxx>
---
Documentation/devicetree/bindings/leds/leds-lm3692x.txt | 3 +++
1 file changed, 3 insertions(+)

diff --git a/Documentation/devicetree/bindings/leds/leds-lm3692x.txt b/Documentation/devicetree/bindings/leds/leds-lm3692x.txt
index 95f6d8c19f20..73f41249ecd3 100644
--- a/Documentation/devicetree/bindings/leds/leds-lm3692x.txt
+++ b/Documentation/devicetree/bindings/leds/leds-lm3692x.txt
@@ -18,6 +18,8 @@ Required properties:
Optional properties:
- enable-gpios : gpio pin to enable/disable the device.
- vled-supply : LED supply
+ - ti,brightness-mapping-exponential: Whether to use exponential
+ brightness mapping
- ti,ovp-microvolt: Overvoltage protection in
micro-volt, can be 17000000, 21000000, 25000000 or
29000000. If ti,ovp-microvolt is not specified it
@@ -49,6 +51,7 @@ led-controller@36 {
enable-gpios = <&gpio1 28 GPIO_ACTIVE_HIGH>;
vled-supply = <&vbatt>;
ti,ovp-microvolt = <25000000>;
+ ti,brightness-mapping-exponential;

led@0 {
reg = <0>;
--
2.23.0