[PATCH v2] iio/gyro/bmg160: Use millidegrees for temperature scale

From: Mike Looijmans
Date: Wed Feb 13 2019 - 02:41:56 EST


Standard unit for temperature is millidegrees Celcius, whereas this driver
was reporting in degrees. Fix the scale factor in the driver.

Signed-off-by: Mike Looijmans <mike.looijmans@xxxxxxxx>
---
v2: Don't touch val2 when returning IIO_VAL_INT
Only touch val when returning a value

drivers/iio/gyro/bmg160_core.c | 6 +++---
1 file changed, 3 insertions(+), 3 deletions(-)

diff --git a/drivers/iio/gyro/bmg160_core.c b/drivers/iio/gyro/bmg160_core.c
index 63ca316..92c07ab 100644
--- a/drivers/iio/gyro/bmg160_core.c
+++ b/drivers/iio/gyro/bmg160_core.c
@@ -582,11 +582,10 @@ static int bmg160_read_raw(struct iio_dev *indio_dev,
case IIO_CHAN_INFO_LOW_PASS_FILTER_3DB_FREQUENCY:
return bmg160_get_filter(data, val);
case IIO_CHAN_INFO_SCALE:
- *val = 0;
switch (chan->type) {
case IIO_TEMP:
- *val2 = 500000;
- return IIO_VAL_INT_PLUS_MICRO;
+ *val = 500;
+ return IIO_VAL_INT;
case IIO_ANGL_VEL:
{
int i;
@@ -594,6 +593,7 @@ static int bmg160_read_raw(struct iio_dev *indio_dev,
for (i = 0; i < ARRAY_SIZE(bmg160_scale_table); ++i) {
if (bmg160_scale_table[i].dps_range ==
data->dps_range) {
+ *val = 0;
*val2 = bmg160_scale_table[i].scale;
return IIO_VAL_INT_PLUS_MICRO;
}
--
1.9.1