[PATCH] dt-bindings: regulator: update fixed-regulator example

From: Johan Hovold
Date: Fri Feb 08 2019 - 09:05:53 EST


Fixed regulators do not have associated bus addresses and are typically
placed directly under the root node where their names must still be
unique despite not having a unit address.

Fix the malformed example node which had a unit address but no "reg"
property by dropping the unit address.

Also, try to make the example more useful by using the recommended
generic node name "regulator", but with a suffix reflecting the
regulator name in order to make it unique.

Signed-off-by: Johan Hovold <johan@xxxxxxxxxx>
---
.../devicetree/bindings/regulator/fixed-regulator.yaml | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/Documentation/devicetree/bindings/regulator/fixed-regulator.yaml b/Documentation/devicetree/bindings/regulator/fixed-regulator.yaml
index a7607b0baab7..d289c2f7455a 100644
--- a/Documentation/devicetree/bindings/regulator/fixed-regulator.yaml
+++ b/Documentation/devicetree/bindings/regulator/fixed-regulator.yaml
@@ -52,9 +52,9 @@ required:

examples:
- |
- abc: fixedregulator@0 {
+ reg_1v8: regulator-1v8 {
compatible = "regulator-fixed";
- regulator-name = "fixed-supply";
+ regulator-name = "1v8";
regulator-min-microvolt = <1800000>;
regulator-max-microvolt = <1800000>;
gpio = <&gpio1 16 0>;
--
2.20.1