Re: [PATCH 11/15] thermal: thermal: Add support for hardware-tracked trip points

From: Mikko Perttunen
Date: Mon May 18 2015 - 15:14:11 EST


On 05/18/2015 09:44 PM, Brian Norris wrote:
On Mon, May 18, 2015 at 02:09:44PM +0200, Sascha Hauer wrote:
On Mon, May 18, 2015 at 12:06:50PM +0300, Mikko Perttunen wrote:
One interesting thing I noticed was that at least the bang-bang
governor only acts if the temperature is properly smaller than (trip
temp - hysteresis). So perhaps we should specify the non-tripping
range as [low, high)? Or we could change bang-bang.

I wonder how we can protect against such off-by-one errors anyway.
Generally a hardware might operate on raw values rather than directly
in temperature values in °C. This means a driver for this must have
celsius_to_raw and raw_to_celsius conversion functions. Now it can
happen that due to rounding errors celsius_to_raw(Tcrit) returns a raw
value that when converted back to celsius is different from the
original value in °C. This would mean the hardware triggers an interrupt
for a trip point and the thermal core does not react because get_temp
actually returns a different temperature than previously programmed as
interrupt trigger. This way we would lose hot (or cold) events.

This also highlights another fact: there's a race between interrupt
generation and temperature reading (->get_temp()). I would expect any
hardware interrupt thermal sensor would also have a latched temperature
reading to correspond with it, and there would be no guarantee that this
latched temperature will match the polled reading seen once you reach
thermal_zone_device_update(). So a hardware driver might report a
thermal update, but the temperature reported to the core won't
necessarily match what interrupt was meant for.

Does this actually matter? The thermal core will reset trips and apply cooling using the new - most recent - value. Using bang bang as example, if the temperature has risen since the interrupt fired, the cooling device will correctly not be switched off. If the temperature has fallen, it will again be correctly switched off. The only issue is then if the temperature is exactly 'trip temp - trip hyst' which will cause set_trips to load the trip points below, but not cause bang bang to turn off the cooling device, and the next chance it will have will only be at the next below trip point. Well, this is still safe (at least until you replace "cooling device" with "heating device"), so maybe it isn't that big of an issue.

Please point out if there's a problem with my line of reasoning.

FWIW - at least Tegra doesn't have a latched register like this. There's just a bit indicating that an interrupt was raised and a temperature register that updates according to the sensor's input clock.


I have a patch that adds a thermal_zone_device_update_temp() API, so
drivers can report the temperature along with the interrupt
notification. (Such a patch also helps so that the driver can choose to
round down on cold events and up on hot events, resolving your rounding
issue too.)

Brian


Cheers,
Mikko

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html