Re: [PATCH 1/2] thermal: exynos: Fix wrong control of power down detection mode for Exynos7

From: Eduardo Valentin
Date: Tue Feb 24 2015 - 13:53:45 EST


On Tue, Feb 24, 2015 at 01:56:54PM +0900, Chanwoo Choi wrote:
> This patch fixes the wrong control of PD_DET_EN (power down detection mode)
> for Exynos7 because exynos7_tmu_control() always enables the power down detection
> mode regardless 'on' parameter.
>
> Cc: Zhang Rui <rui.zhang@xxxxxxxxx>
> Cc: Eduardo Valentin <edubezval@xxxxxxxxx>
> Signed-off-by: Chanwoo Choi <cw00.choi@xxxxxxxxxxx>

Lukasz,

Any objections to this code?

BR,

Eduardo Valentin

> ---
> drivers/thermal/samsung/exynos_tmu.c | 3 ++-
> 1 file changed, 2 insertions(+), 1 deletion(-)
>
> diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c
> index 933cd80..a60f527 100644
> --- a/drivers/thermal/samsung/exynos_tmu.c
> +++ b/drivers/thermal/samsung/exynos_tmu.c
> @@ -682,6 +682,7 @@ static void exynos7_tmu_control(struct platform_device *pdev, bool on)
>
> if (on) {
> con |= (1 << EXYNOS_TMU_CORE_EN_SHIFT);
> + con |= (1 << EXYNOS7_PD_DET_EN_SHIFT);
> interrupt_en =
> (of_thermal_is_trip_valid(tz, 7)
> << EXYNOS7_TMU_INTEN_RISE7_SHIFT) |
> @@ -704,9 +705,9 @@ static void exynos7_tmu_control(struct platform_device *pdev, bool on)
> interrupt_en << EXYNOS_TMU_INTEN_FALL0_SHIFT;
> } else {
> con &= ~(1 << EXYNOS_TMU_CORE_EN_SHIFT);
> + con &= ~(1 << EXYNOS7_PD_DET_EN_SHIFT);
> interrupt_en = 0; /* Disable all interrupts */
> }
> - con |= 1 << EXYNOS7_PD_DET_EN_SHIFT;
>
> writel(interrupt_en, data->base + EXYNOS7_TMU_REG_INTEN);
> writel(con, data->base + EXYNOS_TMU_REG_CONTROL);
> --
> 1.8.5.5
>

Attachment: signature.asc
Description: Digital signature