Re: [PATCH v2] USB: ehci-s5p: Fix phy reset

From: Doug Anderson
Date: Thu Mar 14 2013 - 11:31:30 EST


Hi,

On Thu, Mar 14, 2013 at 7:58 AM, Thomas Abraham
<thomas.abraham@xxxxxxxxxx> wrote:
>> I can see your point, but as I mentioned earlier there seems to be some timing issue here. By simply doing the reset a few ms earlier (in the first probe, before the driver detects that it needs to defer probing), I already can't find the hub on the bus later.
>>
>> So I'm assuming that the same thing would also happen if I put it even earlier in machine init.
>
> True, I missed that point. The usb hub connected over hsic interface,
> after power-on-reset, might have initiated the 'connect' state on
> seeing the idle condition on the bus and since the host/phy controller
> is not ready yet, the connect might have failed.
>
> So the correct sequence would be, after the usb host controller and
> the phy controllers are initialized, the 'reset' pin on the on-board
> usb hub should be asserted. Upon releasing that reset, the usb hub
> would initiate the 'connect' state on the HSIC bus.

I think we ran into similar issues on one of our boards that had a hub
attached to the HSIC port. We had to make our fix in a version of the
code that's nowhere near what landed upstream (so our change is not
relevant), but we're definitely interested in whatever solution you
come up with. :)

-Doug
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/