Re: [PATCH RFC/RFT] regulator: da9052: Ensure the selected voltagefalls within the specified range
From: Mark Brown
Date: Mon Mar 05 2012 - 07:43:33 EST
On Mon, Mar 05, 2012 at 08:27:56PM +0800, Axel Lin wrote:
> Integer division may truncate the result, use DIV_ROUND_UP to ensure the
> selected voltage falls within the specified range.
Applied, thanks.