Thanks for feedback. I have taken care of all your feedback and send
the patch V2.

> > + /* Configure the output discharge path */
> > + st = tps62360_reg_modify_bits(tps, REG_RAMPCTRL, BIT(2), BIT(2));
> > + if (st < 0)
> > + dev_err(tps->dev, "%s() fails in updating reg %d\n",
> > + __func__, REG_RAMPCTRL);
> > +}
>
> I rather suspect that if this is worth doing it's also worth doing over
> suspend...

The discharge path should be only enabled when the output voltage will go to 0.
If it stay in non-zero voltage and enabling discharge path will consume more power.
In suspend, it is not necessarily that voltage output will be 0 and hence it should not
be enabled. In shutdown all power goes off from pmu and hence it is worth to enable
discharge path for quick fall of output voltage.

>
> > + * @vsel: Select the voltage id register.
>
> What's this?
There is 4 sets of voltage configuration register for voltage output. The power
on reset values for this registers are different and selection of the voltage
configuration register is done by 2 pins of the pmu chip which is board dependent.
Based on board connection, it need to be program the desired voltage configuration
Register to achieve the desired output.

--