[PATCH 2/3] acpi: thermal/sysfs-api.txt: document passive attribute for thermal zones

From: Frans Pop
Date: Fri Aug 21 2009 - 04:59:43 EST


Signed-off-by: Frans Pop <elendil@xxxxxxxxx>
Cc: Zhang Rui <rui.zhang@xxxxxxxxx>
Cc: Sujith Thomas <sujith.thomas@xxxxxxxxx>

diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
index 48e9c5c..52b63c4 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.txt
@@ -3,7 +3,7 @@ Generic Thermal Sysfs driver How To

Written by Sujith Thomas <sujith.thomas@xxxxxxxxx>, Zhang Rui <rui.zhang@xxxxxxxxx>

-Updated: 2 January 2008
+Updated: 21 August 2009

Copyright (c) 2008 Intel Corporation

@@ -199,6 +199,16 @@ cdev[0-*]_trip_point
point.
RO, Optional

+passive
+ Attribute is only present for zones which do not have a passive
+ cooling policy (_PSV) defined in ACPI. Default is zero and can be
+ set to a temperature (in millidegrees) to enable a passive trip
+ point for the zone. Activation is done by polling (default interval:
+ 10 seconds); the polling interval can be set in
+ /proc/acpi/thermal/TZN/polling_frequency.
+ Unit: millidegree Celsius
+ RW, Optional
+
*****************************
* Cooling device attributes *
*****************************
@@ -230,8 +240,9 @@ thermal_zone_device (thermal_zone1) with 4 trip points in all.
It has one processor and one fan, which are both registered as
thermal_cooling_device.

-If the processor is listed in _PSL method, and the fan is listed in _AL0
-method, the sys I/F structure will be built like this:
+If the processor is listed in _PSL method, the fan is listed in _AL0
+method, and the zone has a _PSV method, the sys I/F structure will be
+built like this:

/sys/class/thermal:

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html