Re: [PATCH] Pentium Pro - sysenter - doublefault

From: Pavel Machek
Date: Mon Sep 08 2003 - 08:39:33 EST


Hi!

> > I double-checked AP-485 (24161823.pdf, the "real" reference to CPUID),
> > and it says (section 3.4) that SEP is unsupported when the signature
> > as a whole is less that 0x633. This means all PPros, and PII Model 3s
> > with steppings less than 3.
>
> "SEP is unsupported". It's interesting that Pentium Pro erratum #82
> is "SYSENTER/SYSEXIT instructions can implicitly load 'null segment
> selector' to SS and CS registers", implying that SYSENTER does
> _something_ useful on PPros.

Well, with CS==0 machine is not going to survive too long.
If it only happens sometimes you might catch the double fault
and fixup, but....
Pavel
--
Pavel
Written on sharp zaurus, because my Velo1 broke. If you have Velo you don't need...

-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/