2.4.21-pre7 IDE/HPT374 problems

From: lk@trolloc.com
Date: Sat Apr 12 2003 - 13:01:14 EST


I sent a message a few days ago about HPT374 problems, but have a bit of
an update.

I have two Highpoint 1540 adapter (4 port SATA) in a Supermicro
motherboard. Four drives connected to the two adapters in any combination
(i.e. 2 on each adapter, 4 on one adapter, etc.) work fine under
continuous heavy load. 5-6 total drives give me lost interrupts when the
5th or 6th drives are accessed, and the system hangs. 7-8 drives give me
immediate "drive not ready for command" errors on the 7th or 8th drives
(during boot), and when accessed, the system hangs.

I removed one of the Highpoint controllers, and put in two Silicon Image
controllers. I'm still having a similar problem. The 4 drives on the 2
silicon image controllers, and the first two drives on the Highpoint work
fine. The second two drives on the highpoint controller immediately give
me errors:
Apr 11 07:02:54 nfs2 kernel: hds: status error: status=0x58 { DriveReady SeekComplete DataRequest }
Apr 11 07:02:54 nfs2 kernel:
Apr 11 07:02:54 nfs2 kernel: hds: drive not ready for command
Apr 11 07:02:54 nfs2 kernel: hdq: status error: status=0x58 { DriveReady SeekComplete DataRequest }
Apr 11 07:02:54 nfs2 kernel:
Apr 11 07:02:54 nfs2 kernel: hdq: drive not ready for command

Any attempt at accessing those drives just spits out more status errors
until the system hangs.

Attached are lspci -vv and dmesg output.





-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/



This archive was generated by hypermail 2b29 : Tue Apr 15 2003 - 22:00:27 EST