PING www.ee (212.107.32.146): 56 data bytes 64 bytes from 212.107.32.146: icmp_seq=0 ttl=249 time=3.1 ms wrong data byte #34 should be 0x22 but was 0x4 14 15 16 17 18 19 1a 1b 1c 1d 1e 1f 20 21 4 1 43 c0 22 23 24 25 22 23 24 25 22 23 24 25 22 23 24 25 2d c0 0 0 0 0 0 0 0 0 0 0 0 0 64 bytes from 212.107.32.146: icmp_seq=1 ttl=249 time=4.2 ms wrong data byte #34 should be 0x22 but was 0x2 14 15 16 17 18 19 1a 1b 1c 1d 1e 1f 20 21 2 a3 0 0 22 23 24 21 22 23 24 25 22 23 24 25 22 23 24 25 4 c0 0 0 0 0 0 0 0 0 0 0 0 0 --- www.ee ping statistics --- 2 packets transmitted, 2 packets received, 0% packet loss round-trip min/avg/max = 3.1/3.6/4.2 ms Module Size Used by Tainted: P tulip 45440 1 pci-scan 4584 1 [tulip] 3c59x 35864 0 00:0d.0 PCI bridge: Digital Equipment Corporation DECchip 21052 (rev 02) 00:0e.0 ISA bridge: Intel Corp. 82371SB PIIX3 ISA [Natoma/Triton II] (rev 01) 00:0e.1 IDE interface: Intel Corp. 82371SB PIIX3 IDE [Natoma/Triton II] 00:0f.0 Ethernet controller: Digital Equipment Corporation DECchip 21142/43 (rev 30) 01:09.0 Ethernet controller: 3Com Corporation 3c905C-TX [Fast Etherlink] (rev 78) 01:0a.0 Ethernet controller: Accton Technology Corporation EN-1216 Ethernet Adapter (rev 11) 01:0c.0 VGA compatible controller: S3 Inc. 86c988 [ViRGE/VX] (rev 02) 01:0d.0 SCSI storage controller: LSI Logic / Symbios Logic (formerly NCR) 53c875 (rev 03) tulip-diag.c:v2.08 5/15/2001 Donald Becker (becker@scyld.com) http://www.scyld.com/diag/index.html Index #1: Found a Digital DS21143 Tulip adapter at 0x8000. Digital DS21143 Tulip chip registers at 0x8000: 0x00: ffa0e000 ffffffff ffffffff 87bda000 87bda200 f0660000 b3862002 fbfffbff 0x40: e0000000 fff583ff ffffffff fffe0000 000001c4 ffff0001 fffbff7f 8ff00008 Port selection is 100mbps-SYM/PCS 100baseTx scrambler, half-duplex. Transmit started, Receive started, half-duplex. The Rx process state is 'Waiting for packets'. The Tx process state is 'Idle'. The transmit threshold is 128. The NWay status register is 000001c4. EEPROM 64 words, 6 address bits. PCI Subsystem IDs, vendor 0000, device 0000. CardBus Information Structure at offset 00000000. Ethernet MAC Station Address 00:00:F0:51:01:49. EEPROM transceiver/media description table. Leaf node at offset 30, default media type 0800 (Autosense). 4 transceiver description blocks: Media 10baseT, block type 2, length 6. Serial transceiver for 10baseT (media type 0). GP pin direction 08af GP pin data 00a5. Media 10baseT-Full Duplex, block type 2, length 6. Serial transceiver for 10baseT-Full Duplex (media type 4). GP pin direction 08af GP pin data 00a5. Media 100baseTx, block type 4, length 8. SYM transceiver for 100baseTx (media type 3). GP pin direction 08af GP pin data 00a5. No media detection indication (command 80 61). Media 100baseTx Full Duplex, block type 4, length 8. SYM transceiver for 100baseTx Full Duplex (media type 5). GP pin direction 08af GP pin data 00a5. No media detection indication (command 80 61). No MII transceivers found! Internal autonegotiation state is 'Autonegotiation disabled'. Index #2: Found a Accton EN1217/EN2242 (ADMtek Comet) adapter at 0x9000. Accton EN1217/EN2242 (ADMtek Comet) chip registers at 0x9000: 0x00: fff9e000 ffffffff ffffffff 87bdb000 87bdb200 fc06c812 ff970111 fffe5410 0x40: fffe0000 fff597f8 00000000 fffe0000 00000000 00000200 00000000 00000008 Extended registers: 80: 2006c812 03fe5410 a0dc0005 0000ff00 00000000 87bdb260 87bdb1d0 ffe0f000 a0: f0000000 23e20400 ffff6b99 00000000 40000000 00000000 00000000 00000000 c0: 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000 e0: 00000000 00000000 00000000 00000000 00000000 00000000 00000000 f0000027 Comet duplex is reported in the MII status registers. Transmit stopped, Receive stopped, half-duplex. The Rx process state is 'Waiting for packets'. The Tx process state is 'Stopped'. The transmit threshold is 128. Interrupt sources are pending! CSR5 is fc06c812. Tx complete indication. Link passed indication. Timer expired indication. Early Rx indication. Comet MAC address registers 23e20400 ffff6b99 Comet multicast filter 0000000040000000. EEPROM 64 words, 6 address bits. Ethernet MAC Station Address 00:04:e2:23:99:6b. Default connection type 'Autosense'. PCI IDs Vendor 1113 Device 1216 Subsystem 10b8 1255 PCI min_grant 255 max_latency 255. CSR18 power-up setting 0xa0dc****. MII PHY found at address 1, status 0x7869. MII PHY found at address 2, status 0x786d. MII PHY found at address 3, status 0x786d. MII PHY found at address 4, status 0x786d.