Re: 3c59x:command 0x3002 did not complete! Status=0xffff

From: Harald Dunkel (harri@synopsys.COM)
Date: Mon Oct 29 2001 - 16:22:01 EST


Tim Walberg wrote:
>
> Is the NIC sharing interrupts or I/O ports with
> the SCSI HBAs?
>

Nope:

  Bus 0, device 10, function 0:
    SCSI storage controller: Adaptec 7899A (rev 1).
      IRQ 15.
      Master Capable. Latency=32. Min Gnt=40.Max Lat=25.
      I/O at 0xa000 [0xa0ff].
      Non-prefetchable 64 bit memory at 0xd5000000 [0xd5000fff].
  Bus 0, device 10, function 1:
    SCSI storage controller: Adaptec 7899A (#2) (rev 1).
      IRQ 9.
      Master Capable. Latency=32. Min Gnt=40.Max Lat=25.
      I/O at 0x9800 [0x98ff].
      Non-prefetchable 64 bit memory at 0xd4800000 [0xd4800fff].
  Bus 0, device 11, function 0:
    Ethernet controller: 3Com Corporation 3c900 Combo [Boomerang] (rev 0).
      IRQ 10.
      Master Capable. Latency=32. Min Gnt=3.Max Lat=8.
      I/O at 0x9400 [0x943f].

The SCSI controller is an Adaptec 39160, so it allocates 2 IRQs, 2 I/Os,
etc.

Regards

Harri
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/



This archive was generated by hypermail 2b29 : Wed Oct 31 2001 - 21:00:37 EST